Fine Blanking Press Refurbishment and Retrofit
Refurbishment starts with condition evidence, not a generic replacement list. We assess guiding, hydraulics, controls, safety and production symptoms before defining a repair, retrofit or full rebuild scope.
Full Scope of Refurbishment Work
- Guiding column, bushing and ram parallelism restoration
- Hydraulic pump, valve and cylinder overhaul or replacement
- Cracked or worn frame repair welding and stress-relief (case-by-case assessment)
- Control system retrofit โ replacing obsolete relay/PLC controls with modern PLC/HMI
- Servo feeder and lubrication system upgrade or addition
- Repainting, re-wiring and safety guarding upgrade to current standards
- Post-rebuild load testing and precision verification report

Experience Across Major Fine Blanking Press Platforms
Brand names referenced (Feintool, Mori, Schuler, Hydrel, Osterwalder, Asahi-Seiki, Nagano Seiko, etc.) describe equipment platforms our engineers service. Hubei Fine Blanking Machinery Co., Ltd is an independent service provider and is not affiliated with, endorsed by, or an authorized dealer of these manufacturers.
How a Refurbishment Project Runs
Site Survey & Assessment
Our engineer inspects the press on-site (or via remote video) and issues a condition report with recommended scope.
Fixed-Scope Proposal
You receive a itemized quotation covering parts, labor and estimated downtime โ no open-ended billing.
Rebuild Execution
Work is carried out on-site or, for major frame/guiding work, at our facility if logistics allow.
Testing & Sign-Off
Load test, precision measurement and a production trial confirm the press meets the agreed specification before hand-back.
Prepare the Machine Record
- Brand, model, serial number and nameplate photographs
- Maintenance history, alarm log and current production symptoms
- Mechanical, hydraulic and electrical drawings where available
- Current part quality, repeatability and downtime evidence
- Required future output, controls and safety expectations
Choose the Right Intervention
A targeted repair addresses a localized fault. A retrofit replaces an obsolete subsystem while retaining serviceable structure. A full refurbishment is justified when condition measurements show broader wear or multiple systems have reached end of support. For brand-specific diagnosis, review our Feintool and Mori service page.
Ready to discuss your fine blanking project?
Send us your part drawing and volume requirements โ our engineers will respond with a tonnage recommendation and quotation within 24 hours.